ID 110422
| Minimum velocity for homed is greater than the maximum velocity of non-homed axes. | ||||
| Description | The slow homing velocity P-AXIS-00218 may not be greater than the maximum permissible velocity P-AXIS-00268 for non-homed axes. | |||
| Response | Class | 1 | Warning output. The value of P-AXIS-00218 is automatically set to the maximum permissible velocity P-AXIS-00268 for non-homed axes. | |
| Solution | Class | 1 | Set the value for P-AXIS-00218 smaller than the maximum permissible velocity P-AXIS-00268 for non-homed axes. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected. | ||||
| %2: | Current value [1µm/s or 0.001°/s] | |||
| Current value of P-AXIS-00218. | ||||
| %3: | Limit value [1µm/s or 0.001°/s] | |||
| Maximum velocity P-AXIS-00268 for non-homed axes. | ||||
| %4: | Corrected value [1µm/s or 0.001°/s] | |||
| Velocity value corrected to P-AXIS-00268 . | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||