ID 110422

vb_reflow > vb_not_referenced.

Description

The slow speed P-AXIS-00218 of homing must not be greater than the maximum permissible speed P-AXIS-00268 for non-referenced axes.

Response

Class

1

Warning output. The value of P-AXIS-00218 is automatically set to the maximum permissible velocity P-AXIS-00268 for unreferenced axes.

Solution

Class

1

Set the value for P-AXIS-00218 smaller than the maximum permissible velocity P-AXIS-00268 for unreferenced axes.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0,001°/s]

Current value of P-AXIS-00218.

%3:

Limit value [1µm/s or 0.001°/s]

Maximum velocity P-AXIS-00268 for unreferenced axes.

%4:

Corrected value [1µm/s or 0,001°/s]

Speed value corrected to P-AXIS-00268 .

Error type

2, Error message by data transfer from parameter list into control device.