ID 110449

Invalid value for parameter P-AXIS-00318 was corrected.

Description

The ‘Reading absolute position from drive’ function in the axis parameter list was activated by antr.profibus.read_abs_pos_mode (P-AXIS-00315) and no value or a value outside the permissible value range was assigned to the parameter antr.profibus.read_abs_pos_from_drive (P-AXIS-00318).

Response

Class

1

The value of P-AXIS-00318 is automatically corrected.

Solution

Class

1

Change value of P-AXIS-00318 or enter an entry in the axis parameter list.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Error value [-]

Parameterised value of P-AXIS-00318.

%3:

Upper limit value [-]

Permissible maximum value of P-AXIS-00318.

%4:

Corrected value [-]

New value of P-AXIS-00318.

Error type

2, Error message by data transfer from parameter list into control device.