ID 110467

Invalid value for P-AXIS-00321.

Description

Parameter antr.reference_cam_signal (P-AXIS-00321) specified a digital input to read the reference cam signal that does not match the drive type used (see also P-AXIS-00321).

Response

Class

1

Warning and correction of parameter. Correct P-AXIS-00321 to the value “PLC”.

Solution

Class

1

Check and modify P-AXIS-00321; the drive type used must support this value.

Parameter

%1:

Logical axis number [-]

Logical axis number (P-AXIS-00016) of affected axis

%2:

Drive type [-]

Drive type (P-AXIS-00020).

%3:

Error value [-]

Incorrect value of P-AXIS-00321.

%4:

Corrected value [-]

Corrected value of P-AXIS-00321.

Error type

2, Error message by data transfer from parameter list into control device.