ID 110489

Invalid value for parameter P-AXIS-00353 is corrected.

Description

The axis was parameterised as an edge banding axis antr.edge_bending_input_nbr (P-AXIS-00098) and an invalid value was specified for the edge banding input to be used at the drive (parameter P-AXIS-00353).

Response

Class

1

Warning and correction of parameter. P-AXIS-00353 is corrected to 1

Solution

Class

1

In the axis parameter list, assign to parameter P-AXIS-00353 a value valid for the drive type used (P-AXIS-00020). In the actuator, the latch function must be assigned to the digital input used.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Error value [-]

 

%3:

Lower limit value [-]

 

%4:

Upper limit value [-]

 

%5:

Corrected value [-]

 

Error type

2, Error message by data transfer from parameter list into control device.