ID 110511

Only spindles can be operated in open position loop mode.

Description

One axis is to be operated without position controller (controlled operation). This is only possible for spindles. See also P-AXS-00320.

Response

Class

1

Error message output, reset is locked.

Solution

Class

1

Parameterize a different operation mode for the axis (see P-AXIS-00320) and restart the controller.

Parameter

%1:

Logical axis number [-]

Log. Axis number of the axis (see also P-AXIS-00016).

%2:

Drive type [-]

Drive type of the axis (see also P-AXIS-00020).

%3:

Error value [-]

Operation mode configured for the axis (see also P-AXIS-00320).

%4:

Current value [-]

Configured axis type (see P-AXIS-00018)

%5:

Corrected value [-]

Corrected operation mode.

Error type

2, Error message by data transfer from parameter list into control device.