ID 110532
This parameter is not supported for this drive type. | ||||
Description | Parameter P -AXIS-00403 was assigned a value not equal to 0, although the drive type set (see P-AXIS-00020) does not support this function (setting of an offset to the drive absolute position). | |||
Response | Class | 1 | Warning output, P-AXIS-00403 is set to zero. | |
Solution | Class | 1 | P-AXIS-00403 must be set to 0. | |
Parameter | %1: | Logical axis number [-] | ||
Log. Axis number (see also P-AXIS-00016). | ||||
%2: | Drive type [-] | |||
Drive type (see also P-AXIS-00020): | ||||
%3: | Error value [-] | |||
Parameterized value of P-AXIS-00403. | ||||
%4: | Corrected value [-] | |||
Corrected value of P-AXIS-00403. | ||||