ID 110549
Invalid bit number for axis reference test. | |||||
Description | Reference monitoring has been activated, but the bit number configured in P-AXIS-00425 is invalid for reference monitoring. See FCT-M1// Section: Reference loss(Reference monitoring)
The smallest permissible value for P-AXIS-00425 is 0. Depending on the length of the configured telegram element used for transmission of the referenced information the maximum value of this parameter is: | ||||
Telegram element length | Maximum value for P-AXIS-00425 | ||||
2 | 15 | ||||
4 | 31 | ||||
This error message also occurs if no value has been configured for P-AXIS-00425. | |||||
Response | Class | 3 | Reference monitoring is deactivated- | ||
Solution | Class | 1 | P-AXIS-00425 must have a permissible value assigned, or reference monitoring disabled. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Error value [-] | ||||
Current value of P-AXIS-00425. | |||||
%3: | Limit value [-] | ||||
Limit value for P-AXIS-00425. | |||||
%4: | Corrected value [-] | ||||
Corrected value of P-AXIS-00425. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
|