ID 110549

Invalid bit number for axis reference test.

Description

Reference monitoring has been activated, but the bit number configured in P-AXIS-00425 is invalid for reference monitoring.

See FCT-M1// Section: Reference loss(Reference monitoring)

 

The smallest permissible value for P-AXIS-00425 is 0.

Depending on the length of the configured telegram element used for transmission of the referenced information the maximum value of this parameter is:

Telegram element length

Maximum value for P-AXIS-00425

2

15

4

31

This error message also occurs if no value has been configured for P-AXIS-00425.

Response

Class

3

Reference monitoring is deactivated-

Solution

Class

1

P-AXIS-00425 must have a permissible value assigned, or reference monitoring disabled.

Parameter

%1:

Logical axis number [-]

 

%2:

Error value [-]

Current value of P-AXIS-00425.

%3:

Limit value [-]

Limit value for P-AXIS-00425.

%4:

Corrected value [-]

Corrected value of P-AXIS-00425.

Error type

2, Error message by data transfer from parameter list into control device.