ID 110569
Positive absolute ACS manual mode limit is smaller than negative limit. | ||||
Description | The absolute positive movement limit P-AXIS-00493 for the motion range in active manual mode is smaller than the negative software limit switch P-AXIS-00492. Monitoring is disabled. | |||
Response | Class | 1 | None. | |
Solution | Class | 1 | Set positive movement limit P-AXIS-00493 greater than the negative movement limit P-AXIS-00492. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected. | ||||
%2: | Current value [-] | |||
Current value for positive offset limit P-AXIS-00493. | ||||
%3: | Current value [-] | |||
Current value of negative offset limit P-AXIS-00492. | ||||
%4: | Corrected value [-] | |||
Corrected value for positive offset limit P-AXIS-00493. | ||||
%5: | Corrected value [-] | |||
Corrected value for negative offset limit P-AXIS-00492. | ||||
Error type | 2, Error message on data transfer of parameter lists to controller. | |||
|