ID 110569

Positive absolute ACS manual mode limit is smaller than negative limit.

Description

The absolute positive movement limit P-AXIS-00493 for the motion range in active manual mode is smaller than the negative software limit switch P-AXIS-00492. Monitoring is disabled.

Response

Class

1

None.

Solution

Class

1

Set positive movement limit P-AXIS-00493 greater than the negative movement limit P-AXIS-00492.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Current value [-]

Current value for positive offset limit P-AXIS-00493.

%3:

Current value [-]

Current value of negative offset limit P-AXIS-00492.

%4:

Corrected value [-]

Corrected value for positive offset limit P-AXIS-00493.

%5:

Corrected value [-]

Corrected value for negative offset limit P-AXIS-00492.

Error type

2, Error message on data transfer of parameter lists to controller.