ID 110574

Integral time for I position controller exceeds maximum value.

Description

The value set for parameter P-AXIS-00495 is greater than the maximum permissible value.

Response

Class

1

Warning output, P-AXIS-00495 is set to zero.

Solution

Class

1

Reduce the value of P-AXIS-00495

Parameter

%1:

Logical axis number [-]

Axis number

%2:

Incorrect value [1 µs]

Set value of P-AXIS-00495

%3:

Upper limit value [1 µs]

Permissible maximum value.

%4:

Corrected value [1 µs]

Corrected value of P-AXIS-00495

%5:

Current value [-]

Gear index

Error type