ID 110584

Suppression of homing only possible for axis with absolute path measurement system.

Description

Axis parameter P-AXIS-00299 can be used to suppress homing for an axis with the IGNORE_ABS_POS setting. However, this is only permitted for axes with an absolute path measurement system (see P-AXIS-00014).

Response

Class

1

Warning and correct homing type P-AXIS-00299

Solution

Class

1

Correct the homing type P-AXIS-00299 or set the parameter P-AXIS-00014 to the value 1 if an absolute path measurement system is present.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Drive type [-]

Drive type P-AXIS-00020 of the affected axis

%3:

Current value [-]

Current value of parameter P-AXIS-00014 for the identifier of an absolute path measurement system

%4:

Incorrect value [-]

Incorrect setting for parameter P-AXIS-00299 homing type

%5:

Corrected value [-]

Corrected setting for P-AXIS-00299 homing type

Error type

2, Error message on data transfer of parameter lists to controller.