ID 110584
Suppression of homing only possible for axis with absolute path measuring system. | ||||
Description | In axis parameter P-AXIS-00299, the IGNORE_ABS_POS setting can be used to suppress homing for an axis. However, this is only permitted for axes with an absolute position measuring system (see P-AXIS-00014). | |||
Response | Class | 1 | Warning and correction of homing type P-AXIS-00299 | |
Solution | Class | 1 | Correct the homing type P-AXIS-00299 or set the parameter P-AXIS-00014 to the value 1 if an absolute position measuring system is present. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Drive type [-] | |||
Drive type P-AXIS-00020 of the affected axis | ||||
%3: | Current value [-] | |||
Current value of parameter P-AXIS-00014 for signaling absolute measuring system | ||||
%4: | Error value [-] | |||
Incorrect setting for parameter P-AXIS-00299 homing type | ||||
%5: | Corrected value [-] | |||
Corrected setting for P-AXIS-00299 reference type | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|