ID 110584

Suppression of homing only possible for axis with absolute path measuring system.

Description

In axis parameter P-AXIS-00299, the IGNORE_ABS_POS setting can be used to suppress homing for an axis. However, this is only permitted for axes with an absolute position measuring system (see P-AXIS-00014).

Response

Class

1

Warning and correction of homing type P-AXIS-00299

Solution

Class

1

Correct the homing type P-AXIS-00299 or set the parameter P-AXIS-00014 to the value 1 if an absolute position measuring system is present.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Drive type [-]

Drive type P-AXIS-00020 of the affected axis

%3:

Current value [-]

Current value of parameter P-AXIS-00014 for signaling absolute measuring system

%4:

Error value [-]

Incorrect setting for parameter P-AXIS-00299 homing type

%5:

Corrected value [-]

Corrected setting for P-AXIS-00299 reference type

Error type

2, Error message by data transfer from parameter list into control device.