ID 110586
Parametrized measuring signal source not supported for this drive type. | ||||
Description | In parameter P-AXIS-00516 "kenngr.measure.signal" the measuring signal source is defined which is used for a measurement run (e.g. G100). However, the given setting is unsupported with the drive type of the axis. | |||
Response | Class | 1 | Warning and correction of parameter P-AXIS-00516 | |
Solution | Class | 1 | Correct the parameter P-AXIS-00516 for the measuring signal source | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Drive type [-] | |||
Drive type P-AXIS-00020 of the axis | ||||
%3: | Error value [-] | |||
Incorrect setting for measuring signal source P-AXIS-00516 | ||||
%4: | Corrected value [-] | |||
Corrected setting for P-AXIS-00516 measuring signal source | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|