ID 110594

Invalid bit number for additional 'Ready for Power test'.

Description

Additional 'Ready for Power' test was enabled but the bit number configured in P-AXIS-00709 for this test is invalid.

 

The smallest permissible value for P-AXIS-00709 is 0.

Depending on the length of the configured telegram element used to transfer the additional ready for power test information, the maximum value of this parameter is:

Telegram element length

Maximum value for P-AXIS- 00709

2

15

4

31

This error message is also output if no value is configured for P-AXIS-00709.

Response

Class

3

Error message output, ready for power test is disabled.

Solution

Class

1

P-AXIS-00709 must have a permissible value assigned, or disable the ‘Ready for Power' test.

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

Current value of P-AXIS-00709.

%3:

Limit value [-]

Limit value for P-AXIS-00709.

%4:

Corrected value [-]

Corrected value of P-AXIS-00709.

Error type

2, Error message on data transfer of parameter lists to controller.