ID 110600

Invalid value for maximum movement distance from reference cam.

Description

An invalid value was assigned to axis parameter P-AXIS-00531 .

The following restrictions do apply:

P-AXIS-00531 ≥ 0

P-AXIS-00531 ≤ Modulo calculation, for axes for which a modulo calculation is carried out.

Response

Class

1

Warning output, the value is corrected automatically.

If P-AXIS-00531 < 0, the corrected value is 0, if P-AXIS-00531 is larger than the module's upper echo, it is limited to the module's upper echo range.

Solution

Class

1

P-AXIS-00531 must be corrected.

Parameter

%1:

Logical axis number [-]

Axis number

%2:

Error value [0.1 µm or 0,0001°]

Incorrect value of P-AXIS-00531.

%3:

Lower limit value [0.1 µm or 0,0001°]

Minimum permissible value of P-AXIS-00531.

%4:

Upper limit value [0.1 µm or 0,0001°]

Maximum permissible value of P-AXIS-00531.

%5:

Corrected value [0.1 µm or 0.0001°]

Corrected value of P-AXIS-00531.

Error type

2, Error message by data transfer from parameter list into control device.