ID 110603
Weighting factor for acceleration of distance control for lowering movement exceeds maximum permissible value. | ||||
Description | The acceleration (P-AXIS-00416) used for the lowering movement of the distance control [FCT-M3] can be weighted with the factor P-AXIS-00534 in per mille [0.1%]. However, the given weighting factor is greater than permissible. | |||
Response | Class | 1 | Warning, weighting factor for acceleration P-AXIS-00534 is corrected. | |
Solution | Class | 1 | Correct parameter P-AXIS-00534. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected | ||||
%2: | Error value [0.1%] | |||
Invalid weighting value P-AXIS-00534 | ||||
%3: | Upper limit value [0.1%] | |||
Maximum permissible acceleration weighting P-AXIS-00534 | ||||
%4: | Corrected value [0.1%] | |||
Corrected value for acceleration weighting P-AXIS-00534 | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|