ID 110607

Function 'Drive disable on position lag error' is not supported for this drive type.

Description

Parameter P-AXIS-00537 was set to "ON", although the configured drive type does not support this function.

Response

Class

1

Warning output, correction of P-AXIS-00537.

Solution

Class

1

Set P-AXIS-00537 to "OFF" or "DEFAULT".

Parameter

%1:

Logical axis number [-]

Axis number (P-AXIS-00016)

%2:

Drive type [-]

Drive type (P-AXIS-00020)

%3:

Error value [-]

Parameterized value of P-AXIS-00537.

%4:

Corrected value [-]

Corrected value of P-AXIS-00537.

Error type

2, Error message by data transfer from parameter list into control device.