ID 110609

An invalid bit number was entered for the 'value_latched' signal.

Description

When configuring the SERCOS real-time status bits for the signal 'value latched probe 1/2', an invalid bit number was entered either in P-AXIS-00678 (probe 1) or in P-AXIS-00684 (probe 2).

Response

Class

3

An error message is output containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset in order to prevent the execution of measurement run or edge banding with incompletely configured probes.

Solution

Class

1

Correct P-AXIS-00678/or P-AXIS-00684.

Parameter

%1:

 

Log. axis number

%2:

 

Incorrect value of P-AXIS-00678/or P-AXIS-00684

%3:

 

Permissible minimum value.

%4:

 

Permissible maximum value.

Error type

2, Error message on data transfer of parameter lists to controller.