ID 110621

Invalid parameterisation of spindle homing. Homing switch evaluation is activated.

Description

The parameterisation of the spindle homing is invalid. Homing without a homing switch (kenngr.ref_ohne_nocken 1) must be performed without direction reversal (kenngr.ref_ohne_rev 1). Valid settings for these two parameters are:

 

ref_ohne_rev = FALSE

ref_ohne_rev = TRUE

ref_ohne_nocken = FALSE

conventional homing

flying homing with cam

Invalid parameterisation of spindle homing. Homing switch evaluation is activated.

impermissible setting

flying homing without cam

Response

Class

1

Spindle homing is executed with evaluation of homing switch

Solution

Class

1

Correct parameter P-AXIS-00156 or P-AXIS-00157

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Current value [-]

Axis type P-AXIS-00018 of the affected axis.

%3:

Incorrect value [-]

Homing with/without cam P-AXIS-00156.

%4:

Incorrect value [-]

Homing with/without direction reversal P-AXIS-00157.

Error type

2, Error message on data transfer of parameter lists to controller.