ID 150104

Inadmissible value for handwheel counter address (P-MANU-00004).

Description

The manual mode parameters are read and interpreted by the CNC.

 

The CNC detects that a value for manual mode parameters P-MANU-00004 exceeds the CNC system internal limit.

 

Parameter P-MANU-00004 indicates the address to which the handwheel counters are sent to the CNC. When this message is displayed, the high-level interface to the PLC was defined as the transfer location (see P-MANU-00003). The HLI interface selected to transfer the handwheel counter reading is defined in parameter P-MANU-00004 .

Response

Class

3

Manual mode parameters are not transferred to the CNC.

Solution

Class

6

Correct the value for P-MANU-00004,
P-MANU-00004 <= the limit value (see parameter 2 of the message).

Reinterpret manual mode parameters by restarting CNC system.

Parameter

%1:

Current value [-]

Index of interface to transfer handwheel counter reading to CNC defined in manual mode parameter data record.

%2:

Limit value [-]

Maximal allowed index value.

%3:

Logical identifier of control element [-]

Identifier of logical control element whose parameters caused the message.

Error type

2, Error message on data transfer of parameter lists to controller.