ID 292015

Kinematic transformation: Iteration counter overflow.

Description

Iterative transformation algorithm with active kinematic transformation (#RTCP ON, #TRAFO ON) does not provide a valid result. Can occur, for example, if moving to a singular axis position was done.

If machine is not referenced this error also can occur because of wrong or invalid axis positions.

For more information on kinematic transformation see
[PROG// Section: Rotation Tool Centre Point (RTCP)]
[KITRA//Introduction]

Response

Class

-

Depending on the module where error occurs:

  • Abort NC program processing.
  • Movement stop.

Solution

Class

-

Move in valid axis position range.

Parameter

%1:

Current value [-]

ID of incorrectly configured kinematic

%2:

Current value [-]

Internal ID of error cause (for diagnosis by specialist only)

Error type

-