ID 60241

Programmed velocity exceeds speed monitoring limit.

Description

The programmed velocity exceeds the maximum permissible actual velocity P-AXIS-00311 with velocity monitoring switched on (P-AXIS-00312).

If P-AXIS-00311 is zero or is not specified, the limit value for velocity monitoring is set to P-AXIS-00268.

Response

Class

6

Stop the axis and abort the NC program.

Solution

Class

6

Set the programmed velocity to less than the maximum permissible actual velocity P-AXIS-00311

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [1µm/s or 0.001°/s]

Current value of the programmed velocity.

%3:

Error value [1µm/s or 0.001°/s]

Incorrect value of the programmed velocity.

%4:

Limit value [1µm/s or 0.001°/s]

Maximum permissible value of the actual velocity P-AXIS-00311.

Error type

1, Error message from NC program.