ID 50962

Start position in protection area..

Description

The start position in manual mode is outside the protection area when workspace and protection area monitoring is active [FCT-C14// Special features in manual mode].

This is not possible with the selected setting of P-CHAN-00442.

Response

Class

6

Abrupt stop for all axes.

Solution

Class

6

Check the protection area, check P-CHAN-00442. Set the Suppress error output from workspace monitoring in manual mode control unit to move backward in the protection area in manual mode.

Parameter

%1:

Identification number [-]

ID of the affected protection area

%2:

Current value [-]

Bit identifier of the affected axes

%3

Error value [0.1 10^-3 mm or ø]

3-dimensional output of positions

Error type

1, Error message from NC program.