Restrictions – special features

The FIR filters and the Vibration Guard are different independent functions with similar objectives. Both functions smooth the axis setpoint signal to avoid exciting the machine to vibrations. FIR filters achieve this in the broadband. On the other hand, the Vibration Guard filters specific critical frequencies selectively.

Attention

attention

It is only possible to use FIR filters and the Vibration Guard simultaneously under certain conditions.

The following combinations are not possible and will result in the output of an error message:

It is permitted to use:

Axis exchange commands

Notice

notice

Axis exchange commands disable FIR filters.

Axis exchange commands disable FIR filters that may be enabled at that time. If the filters should remain enabled after axis exchange, they must be re-enabled by a corresponding #FILTER command.

If the FIR filters were only enabled in the axis lists (P-AXIS-00573), the filters remain enabled even after axis exchange.