ID 110644

Could not allocate enough memory for table of plane compensation.

Description

The parameter P-COMP-00061 (max_points) sets how many inputs are allocated to the table of the plane compensation [FCT-C5).

 

Not enough memory could be allocated for this request.

Response

Class

6

List interpretation is aborted.

Solution

Class

6

Either:

  • make more memory space available, or
  • reduce the value of P-COMP-00061 (max_points) and then reboot the controller

Parameter

%1:

Logical axis number [-]

Logical axis number (P-AXIS-00016) of axis affected.

%2:

Current value [-]

Name of the list file

%3:

Error value [-]

Requested number of table inputs

%4:

Limit value [-]

Maximum number of table inputs available

Error type

2, Error message by data transfer from parameter list into control device.