ID 110652
Position controller and interpolator position cannot be restored at the same time. | ||||
Description | The parameter P-AXIS-00402 restores the last interpolator position of the axis for PLC axis couplings at controller start-up. On the other hand, the parameter P-AXIS-00761 loads the last position controller position of the axis. The two parameters are therefore mutually exclusive. | |||
Response | Class | 1 | The function to restore the last position controller position is disabled. | |
Solution | Class | 1 | Correct parameter P-AXIS-00402 or P-AXIS-00761. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis. | ||||
%2: | Drive type [-] | |||
Drive type P-AXIS-00020 of the affected axis | ||||
%3: | Current value [-] | |||
Current value of P-AXIS-00402 to restore the interpolator position | ||||
%4: | Error value [-] | |||
Current value of P-AXIS-00761 to restore the last position controller position | ||||
%5: | Corrected value [-] | |||
Corrected value for P-AXIS-00761 to restore the last position controller position | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|