Minimum path to activate fixed stop detection (P-AXIS-00771)
P-AXIS-00771 | Minimum path to activate fixed stop detection | |
Description | This parameter defines how far to travel in the motion block before fixed stop detection is activated. The value specified is a distance within the motion block. If the value is less than 0, this parameter is set to 0 so that fixed stop detection is activated at the start of the block. A value of zero activates fixed stop detection immediately at the start of the block. If P-AXIS-00772 is parameterised at the same time, the smaller block motion path defined by the two parameters is used as the minimum path. When measuring with several axes, the smallest block motion path of all axes involved in the measurement is used as the minimum path. | |
Parameter | antr.fixed_stop.detect.start_distance | |
Data type | SGN32 | |
Data range | 0 < P-AXIS-00771 < MAX(SGN32) | |
Axis types | <T, R> | |
Dimension | T: 0.1 µm | R: 10-4 ° |
Default value | -1 | |
Drive types | ---- | |
Remarks | If the function ‘Measuring travel to fixed stop’ is used and the value of parameter P-AXIS-00776 is less than 0, the parameter is used as the limit value for fixed stop detection. Currently this parameter only acts with measuring travel to fixed stop if P-AXIS-00776 is not parameterised. Parameter available as of CNC Build V2.11.2810.01 and higher |