Maximum position change for fixed stop detection when measuring travel on fixed stop (P-AXIS-00778)

P-AXIS-00778

Maximum permitted position change during fixed stop detection when measuring travel to fixed stop

Description

This parameter defines the maximum path which may be travelled in the time defined by P-AXIS-00775 to detect the fixed stop. Together with P-AXIS-00775 , an average velocity is defined but this may not be exceeded to detect the fixed stop.

If the value is less than 0, the system checks whether P-AXIS-00773 has a value greater than or equal to zero and, if necessary, this is used; otherwise, velocity monitoring for fixed stop detection is deactivated.

Parameter

kenngr.measure.fixed_stop_detect.max_delta_position_window

Data type

SGN32

Data range

MIN(SGN32) < P-AXIS-00778 ≤ MAX(UNS32)

Axis types

<T, R>

Dimension

T: 0.1 µ

R: 10e-4 °

Default value

-1

Drive types

----

Remarks

Parameter available as of CNC Build V2.11.2810.xx ??