ID 51046

The measured position is before the trigger position for probing in the movement block.

Description

When measuring to a fixed stop, a measured value was acquired before the configured enable position for acquiring the measured value (P-AXIS-00776, P-AXIS-00777).

The output of this error message can be suppressed by the channel parameter P-CHAN-00312. In this case, it is necessary to check whether a correct measurement was performed by checking the variable V.A.MERF.*.

Response

Class

6

Error message output abort program.

Solution

Class

4

Check parameterisation for measuring travel to fixed stop.
P-AXIS-00774, P-AXIS-00775, P-AXIS-00776, P-AXIS-00777, P-AXIS-00778

Parameter

%1:

Logical axis number [-]

Logical axis number (P-AXIS-00016) of axis concerned.

%2:

Error value [0.1 10^-7 mm or ø]

Command position in the current cycle

%3:

Current value [0.1 10^-7 mm or ø]

Actual value in the current cycle

%4:

Current value [%]

Distance covered in movement block

%5:

Current value [%]

Configured minimum path (P-AXIS-00776, P-AXIS-00777)

Error type

1, Error message from NC program.