ID 110655
Tv factor P-AXIS-00765 for distance control is out of permissible range. | ||||
Description | The parameter P-AXIS-00508 indicates the cut-off frequency of the low-pass filter of the distance control. This may not be less than the specified value. | |||
Response | Class | 1 | Output the warning and limit P-AXIS-00508 | |
Solution | Class | 1 | Check and modify P-AXIS-00508. | |
Parameter | %1: | Logical axis number [-] | ||
| ||||
%2: | Error value [Hz] | |||
| ||||
%3: | Lower limit value [Hz] | |||
| ||||
%4: | Corrected value [Hz] | |||
| ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|