ID 110665

Tv factor P-AXIS-00765 for distance control is out of permissible range.

Description

The parameter P-AXIS-00508 indicates the cut-off frequency of the low-pass filter of the distance control. This may not be less than the specified value.

Response

Class

1

Output the warning and limit P-AXIS-00508

Solution

Class

1

Check and modify P-AXIS-00508.
Update the parameters.

Parameter

%1:

Logical axis number [-]

 

%2:

Error value [Hz]

 

%3:

Lower limit value [Hz]

 

%4:

Corrected value [Hz]

 

Error type

2, Error message by data transfer from parameter list into control device.