Abort a measuring block with Delete distance to go
If a measurement run is aborted with Delete distance to go, the behaviour depends on the measurement type used (P-CHAN-00057).
Measurement types 1 to 7
If the measuring block is aborted with Delete distance to go, the NC program continues from the point of interruption. The measuring process is aborted. If the parameter ERR_NO_SIGNAL is set in the NC command #MEAS, warning ID 51058 is output. This signals that the parameter was overwritten.
Measurement type 8 (measurement via several movement sets in connection with edge banding)
If a motion block is aborted in the measuring process and is not the last motion block, NC program processing is continued from the point of interruption. The behaviour is identical to the normal process of Delete distance to go. The measuring process remains active.
If the last measuring block is aborted, error ID 50057 is output. With this measurement type, there must always be a measured value at the end of the measurement.