ID 70625

No correction table available for crosstalk compensation.

Description

An axis in the axis parameters is selected for crosstalk compensation (P-AXIS-00785). However, the compensation value table which contains the required compensation values is missing.

Response

Class

7

Controlled axis stop and disabling of crosstalk compensation

Solution

Class

7

If crosstalk compensation is activated for an axis, a compensation value list must also be specified for it in the start-up list P-STUP-00016,, P-STUP-00017, P-STUP-00036).

Example (extract from start up list):

zahl_kw                                 1

achs_kw[0]                            ..\listen\achskw3.lis

achs_kw_log_ax_nr[0]          3

Parameter

%1:

Logical axis number [-]

Logical axis number of concerned axis, see P-AXIS-00016

Error type

11, Error message from position controller.