ID 70630
Parametrized greatest index of crosstalk compensation table exceeds limits. | ||||
Description | In the compensation value list, parameter P-COMP-00065 for crosstalk compensation specifies the value (starting at 0) of the index of the last valid entry in the compensation value list for crosstalk compensation. When interpreting this list, the CNC checks whether the parameterised value for the index is within the limits provided for crosstalk compensation. | |||
Response | Class | 7 | Controlled stop of axis, crosstalk compensation is disabled. | |
Solution | Class | 7 | Check the value in parameter P-COMP-00065 The value must be within the specified limits of the error message. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of concerned axis, see P-AXIS-00016 | ||||
%2: | Error value [-] | |||
Value specified by the user in parameter P-COMP-00065 for the index of the last valid entry in the compensation value list for crosstalk compensation. | ||||
%3: | Lower limit value [-] | |||
Under limit value, P-COMP-00065 must be greater than or equal to this value. | ||||
%4: | Upper limit value [-] | |||
Upper limit value, P-COMP-00065 must be less than or equal to this value. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|