Residual torque to detect a fixed stop during homing to a fixed stop (P-AXIS-00820)

P-AXIS-00820

Residual torque to detect a fixed stop during homing to a fixed stop

Description

This parameter defines the percentage torque to detect a fixed stop. It refers to the reduced torque that is written to the drive using the drive identifier for moving to a fixed stop. P-AXIS-00719.

 

If this parameter is zero, the general parameter P-AXIS-00818 is used.

If this is also zero, torque is not used to detect a fixed stop.

Parameter

kenngr.homing.torq_detect_torque_limit

Data type

UNS16

Data range

0 ≤ P-AXIS-00820 ≤ 1000

Axis types

T, R, S

Dimension

T: 0.1%

R,S: 0.1%

Default value

0

Drive types

Simulation, SERCOS, CANopen

Remarks

This parameter replaces the parameter P-AXIS-00343.

Parameter available as of V3.1.3080.11