ID 110688

Main and secondary encoders cannot use the same signal.

Description

The same signal was used for the main and secondary encoders. This is not permitted.

Response

Class

1

Warning output. The value for the secondary encoder is not used.

Solution

Class

1

Check and modify the parameter settings of P-AXIS-00823 and P-AXIS-00824. Parameterise different signals.

Parameter

%1:

Logical axis number [-]

Logical axis number (Axis parameters) of the drive.

%2:

Error value [-]

Parameterised signal of the main encoder.

%3:

Error value [-]

Parameterised signal of the secondary encoder.

Error type

2, Error message by data transfer from parameter list into control device.