ID 21548

M function is not freely available or requires a configured spindle.

Description

A programmed M3, M4, M5, M19 or M40 - M45 cannot be executed because either there is no spindle in the NC channel or the the M function is not enabled for general use.

Response

Class

2

Abort NC program processing.

Solution

Class

3

In the channel parameters, correct the parametrisation of the use of M3, M4, M5, M19 and M40 - M45:

Either at least one spindle must be completely configured in the NC channel (P-CHAN-00082 et seq.)...

...or the spindle-specific link of the M function must be disabled:

- P-CHAN-00098 for M3, M4, M5, M19

- P-CHAN-00052 et seq. for M40 - M45

Parameter

%1:

Error value [-]

Number of spindles configured in NC channel (P-CHAN-00082)

%2:

Error value [-]

Value of release parameter (P-CHAN-00098, P-CHAN-00052)

%3:

Current value [-]

Number of M function

Error type

1, Error message from NC program.