ID 50688

Axis not at standstill! Update of filter parameters not possible! Changes are discarded!

Description

A list update or the #MACHINE DATA command changed parameters of the axis filter ([FCT-A7//Section: Parameter overview]). However, this is only permitted when the axis is stationary.

 

Response

Class

3

Error messages; new parameters are not accepted

Solution

Class

7

Repeat the parameter update when the axis is at standstill

Parameter

%1:

Current value [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Current value [-]

Index of the filter affected

%3:

Current value [-]

TRUE : Axis filter has reached the target position

%4:

Current value [-]

TRUE : Command values are output to the axis, i.e. the axis moves

Error type

-

 

Attention

attention

The changed filter parameters have no effect in the controller. The changes are discarded.