Axis not in standstill! Update of filter parameters not possible. Changes are dismissed!
Description
A list update or the #MACHINE DATA command changed parameters of the axis filter ([FCT-A7//Section:Parameter overview]) changed. However, this is only permitted when the axis is stationary.
Response
Class
3
Error messages, new parameters are not accepted
Solution
Class
7
Retry the parameter update when the axis is in standstill
Parameter
%1:
Current value[-]
Logical axis number P-AXIS-00016 of concerned axis
%2:
Current value[-]
Index of the concerned filter
%3:
Current value[-]
TRUE : filter has reached the target position
%4:
Current value[-]
TRUE : Command values are generated for the axis, the axis moves
Error type
-
Attention
The changed filter parameters are not effective in the controller! The changes are dismissed!