ID 70088

Range of set point exceeded.

Description

The value for the manipulated variable currently calculated by the position controller exceeds the permissible value range.

 

Possible causes:

  • Excessive gain factor in the position controller
  • Incorrect normalisation of the manipulated variable
  • Position lag of the axis is too large

 

Possible solutions:

Response

Class

5

Abrupt axis stop for defective axis

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis, see P-AXIS-00016

%2:

Drive type [-]

Drive type of axis affected, see P-AXIS-00020[-]

%3:

Current value [-][-]

Current value of the manipulated variable

%4:

Upper limit value [-]

Maximum permissible value of the manipulated variable

%5:

Block number [-][-][-][-][-]

Block number of the NC program where the error occurred

Error type

11, Error message from position controller.