ID 70088

Value range exceeded.

Description

The value for the manipulated variable currently calculated by the position controller exceeds the permissible value range.

 

Possible causes:

  • Too much gain factor in the position controller
  • Incorrect scaling of the manipulated variable
  • Position lag of the axis is too large

 

Possible solutions:

  • Check manipulated variable scaling (see P-AXIS-00128, P-AXIS-00129)
  • Reduce gain factor (see P-AXIS-00099) of position controller (or increase gain in drive)

Response

Class

5

Abrupt axis stop for defective axis

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis see P-AXIS-00016

%2:

Drive type [-]

Drive type of concerned axis, see P-AXIS-00020[-]

%3:

Current value [-][-]

Current value of the manipulated variable

%4:

Upper limit value [-]

Maximum permissible value of the manipulated variable

%5:

Block number [-][-][-][-][-]

Block number of the NC program, in which the error occurred

Error type