Setting/resetting of bits is not supported for this communication type.
|
Description
| In axis parameter P-AXIS-00399, 'BITARRAY_16' or 'BITARRAY_32' was configured as data type, although bitwise writing of drive values is not supported for the communication type configured in P-AXIS-00397.
See also: [PROG// Section: Drive-independent switching of drive functions]
|
Response
| Class
| 7
| Error message output, evaluation of drive functions is aborted.
|
Solution
| Class
| 6
| Customize either P-AXIS-00399 or P-AXIS-00397.
|
Parameter
| %1:
| Logical axis number [-]
|
|
%2:
| Current value [-]
|
Name of the configured drive function (P-AXIS-00396).
|
%3:
| Drive type [-]
|
Drive type (P-AXIS-00020).
|
%4:
| Error value [-]
|
Configured communication type (P-AXIS-00397).
|
%5:
| Error value [-]
|
Configured data type (P-AXIS-00399).
|