ID 70402

Setting/resetting of bits is not supported for this communication type.

Description

In axis parameter P-AXIS-00399, 'BITARRAY_16' or 'BITARRAY_32' was configured as data type, although bitwise writing of drive values is not supported for the communication type configured in P-AXIS-00397.

See also: [PROG// Section: Drive-independent switching of drive functions]

Response

Class

7

Error message output, evaluation of drive functions is aborted.

Solution

Class

6

Customize either P-AXIS-00399 or P-AXIS-00397.

Parameter

%1:

Logical axis number [-]

 

%2:

Current value [-]

Name of the configured drive function (P-AXIS-00396).

%3:

Drive type [-]

Drive type (P-AXIS-00020).

%4:

Error value [-]

Configured communication type (P-AXIS-00397).

%5:

Error value [-]

Configured data type (P-AXIS-00399).

Error type

-