ID 110403

The maximum velocity of slave axis may not be set to 0.

Description

During velocity synchronisation (camming and gearing) and with synchronisation of camming, the maximum velocity P-AXIS-00302 for a slave axis may not be assigned zero.

Response

Class

1

Warning output. The value for the maximum slave velocity P-AXIS-00302 is automatically set to the maximum permissible axis velocity P-AXIS-00212.

Solution

Class

1

Set value for P-AXIS-00302 greater than zero.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0.001°/s]

Current value of P-AXIS-00302.

%3:

Corrected value [1µm/s or 0.001°/s]

Corrected value of P-AXIS-00302.

Error type

2, Error message on data transfer of parameter lists to controller.