ID 110570
Negative absolute ACS manual mode limit is smaller than negative limit switch. | ||||
Description | The absolute negative movement limit P-AXIS-00492 for the motion range in active manual mode is smaller than the negative software limit switch P-AXIS-00177. The negative absolute movement limit is set to the negative software limit switch. | |||
Response | Class | 1 | None. | |
Solution | Class | 1 | Set negative movement limit P-AXIS-00492 greater than negative software limit switch. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected. | ||||
%2: | Current value [-] | |||
Current value of negative movement limit P-AXIS-00492. | ||||
%3: | Limit value [-] | |||
Current value for negative software limit switch P-AXIS-00177. | ||||
%4: | Corrected value [-] | |||
Corrected value for negative movement limit P-AXIS-00492. | ||||
Error type | 2, Error message on data transfer of parameter lists to controller. | |||
|