ID 110570

Negative absolute ACS manual mode limit is smaller than negative limit switch.

Description

The absolute negative movement limit P-AXIS-00492 for the motion range in active manual mode is smaller than the negative software limit switch P-AXIS-00177. The negative absolute movement limit is set to the negative software limit switch.

Response

Class

1

None.

Solution

Class

1

Set negative movement limit P-AXIS-00492 greater than negative software limit switch.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Current value [-]

Current value of negative movement limit P-AXIS-00492.

%3:

Limit value [-]

Current value for negative software limit switch P-AXIS-00177.

%4:

Corrected value [-]

Corrected value for negative movement limit P-AXIS-00492.

Error type

2, Error message on data transfer of parameter lists to controller.