ID 120471
Oscillation movement outside SLS. | ||||
Description | The oscillation movement of oscillating axis exceeds software limit switches. For more information on oscillation movement, see [FCT-A8// Section: Description | |||
Response | Class | 2 | Program execution stop. | |
Solution | Class | 6 | Check oscillation zero position and excursion, or oscillation reversal positions. Programming of oscillation movement inside software limits. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis. | ||||
%2: | Current value [0.1 10^-3 mm or ø] | |||
Oscillation reversal position 1. | ||||
%3: | Current value [0.1 10^-3 mm or ø] | |||
Oscillation reversal position 2. | ||||
%4: | Lower limit value [0.1 10^-3 mm or ø] | |||
Negative software limit switch P-AXIS-00177 | ||||
%5: | Upper limit value [0.1 10^-3 mm or ø] | |||
Positive software limit switch P-AXIS-00178 | ||||
Error type | 1, Error message from NC program. | |||
|