ID 120471

Oscillating motion outside software limit switches.

Description

The programmed motion of the oscillating axis exceeds software limit switches.

For more information on oscillating motion, see

[FCT-A8// Section: Description
[PROG// Section: Oscillating axes].

Response

Class

2

Program abort.

Solution

Class

6

Check oscillation zero position and excursion or the oscillation reversal positions.

Program oscillating motion inside software limits.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Current value [0.1 10^-3 mm or ø]

Oscillation reversal position 1.

%3:

Current value [0.1 10^-3 mm or ø]

Oscillation reversal position 2.

%4:

Lower limit value [0.1 10^-3 mm or ø]

Negative software limit switch P-AXIS-00177

%5:

Upper limit value [0.1 10^-3 mm or ø]

Positive software limit switch P-AXIS-00178

Error type

1, Error message from NC program.