ID 120471

Oscillation movement outside SLS.

Description

The oscillation movement of oscillating axis exceeds software limit switches.

For more information on oscillation movement, see

[FCT-A8// Section: Description
[PROG// Section: Oscillating axes].

Response

Class

2

Program execution stop.

Solution

Class

6

Check oscillation zero position and excursion, or oscillation reversal positions.

Programming of oscillation movement inside software limits.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [0.1 10^-3 mm or ø]

Oscillation reversal position 1.

%3:

Current value [0.1 10^-3 mm or ø]

Oscillation reversal position 2.

%4:

Lower limit value [0.1 10^-3 mm or ø]

Negative software limit switch P-AXIS-00177

%5:

Upper limit value [0.1 10^-3 mm or ø]

Positive software limit switch P-AXIS-00178

Error type

1, Error message from NC program.