ID 70622

Master axis for crosstalk compensation not available.

Description

The specified master axis for crosstalk compensation does not exist.

Response

Class

7

Controlled stop of concerned axis

Solution

Class

7

Specify a valid logical axis number, see P-COMP-00063

Parameter

%1:

Logical axis number [-]

Logical axis number of concerned axis, see P-AXIS-00016

%2:

Logical axis number [-]

Specified logical axis number of the master axis, which is not present. (see P-COMP-00063)

%3:

Drive type [-]

Drive type of concerned axis, see P-AXIS-00020

%4:

Block number [-]

Block number of the NC program, in which the error occurred

Error type

2, Error message by data transfer from parameter list into control device.