ID 70622

Master axis for crosstalk compensation not available.

Description

The specified master axis (P-COMP-00063) for crosstalk compensation does not exist.

Response

Class

7

Controlled stop of axis affected

Solution

Class

7

Specify a valid logical axis number, see P-COMP-00063

Parameter

%1:

Logical axis number [-]

Logical axis number of axis affected, see P-AXIS-00016

%2:

Logical axis number [-]

Specified logical axis number of the master axis which does not exist. (see P-COMP-00063)

%3:

Drive type [-]

Drive type of axis affected, see P-AXIS-00020

%4:

Block number [-]

Block number of the NC program where the error occurred

Error type

2, Error message by data transfer from parameter list into control device.