Old probing signal parameters (up to version V2.11.2019.14)

P-AXIS-00113

Pulse edge

Description

This parameter defines the measurement signal edge at which the actual value counter executes the latch point.

Parameter

kenngr.mess_neg_flanke

Data type

BOOLEAN

Data range

0: Latch at positive edge of pulse

1: Latch at negative edge of pulse

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

----

Remarks

 

P-AXIS-00115

Measurement signal via axis specific control bit mask

Description

To allow external measurement signals to be taken into account as well, one bit in the axis-specific control bit mask is treated as the measurement signal. This possibility is defined by this parameter.

Parameter

kenngr.mess_signal_achs_steuer

Data type

BOOLEAN

Data range

0/1

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

----

Remarks

 

Measurement method

P-AXIS-00117
(mess_signal_taster)

P-AXIS-00116
(mess_signal_sercos)

P-AXIS-00115
(mess_signal_achs_steuer)

Drive
simulation

X

-

X

Conventional
drive interface

X

-

X

SERCOS
drive interface

X

X

X

P-AXIS-00116

Measurement with SERCOS drives

Description

Measurement with SERCOS drives can be performed with two different methods. The flag defines the measurement signal to be read in via the SERCOS interface.

Parameter

kenngr.mess_signal_sercos

Data type

BOOLEAN

Data range

0: Request from a measurement probe

1: Usage of measurement function supplied by the drive (SERCOS measurement)

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

SERCOS

Remarks

For the measurement with SERCOS drives, the parameters P-AXIS-00060 or P-AXIS-00106 are also required.

P-AXIS-00117

Measurement signal from hardware interface

Description

This parameter selects the use of the NC kernel hardware interface.

Parameter

kenngr.mess_signal_taster

Data type

BOOLEAN

Data range

0/1

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

----

Remarks

 

P-AXIS-00257

Measurement signal via HLI Control Unit

Description

This parameter can determine that the probing signal is read from the HLI via the control unit PLC parameters and not via the cyclical drive interface. The probing value is the actual value at the moment of the occurrence of the probing signal.

Parameter

kenngr.probing_signal_via_plc

Data type

BOOLEAN

Data range

0/1

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

----

Remarks

Due to the scanning of the probing signal in the cycle time of the PLC, the accuracy of the probed value is less than the accuracy achieved by using drive-internal probing latches.

P-AXIS-00330

Measurement with movement to a fixed stop

Description

This parameter enables the measurement signal source 'Fixed stop'.

Parameter

kenngr.meas_signal_fixed_stop

Data type

BOOLEAN

Data range

0/1

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

Conventional, SERCOS, Terminal, Lightbus, Profidrive, CANopen

Remarks

The user must ensure that, during movement to a fixed stop in the drives affected, a torque limitation is active and the velocity is low enough.

All other measurement signal sources (e.g. P-AXIS-00116) must be deselected.

For measurement with movement to a fixed stop, the parameters P-AXIS-00331 or P-AXIS-00332 are also required.